Equipment


Optical emission spectrometer Agilent 720 ICP-OES

Designed for simultaneous express determination of up to 73 elements of the periodic table in a liquid sample medium in 35 seconds.

Gas chromatograph Agilent 7890B

Designed for qualitative and quantitative analysis of complex mixtures of organic compounds, as well as mixtures of gases in a wide range of concentrations.

Thermogravimetric analyzer ELTRA TGA Thermostep

Designed to determine moisture, volatile matter and ash content according to a user-defined program in one analysis, simultaneously analyzes 19 samples with a weight of up to 5 grams and a maximum oven temperature of up to 1000 °C.

 

Vibratory Disc Mill Retsch RS 200

Designed for extremely fast grinding to analytical fineness without loss of medium-hard, brittle and fibrous substances. Mainly used for sample preparation for spectral analysis.

Muffle furnace Carbolite ELF 11/14

Designed to heat a variety of materials to a certain temperature.

 

Drying cabinet Carbolite PF60

It is intended for drying samples of coal, various products, processing of tools and carrying out various laboratory studies, during which a constant temperature is required, reaching from ± 5 – 300 ° C.

 

Analytical balance Radwag XA110/Y

They provide an opportunity to carry out a detailed selection of operation parameters using a modifiable user menu. The balance is equipped with an automatic internal adjustment system that uses standard weight data pre-installed in the system. Installation of scales by level is controlled by the system Level SENSING system, which is a patented technology RADWAG, including an electronic level.

Laboratory scales Radwag PS4500/X

Allows multiple (up to 100 times) extraction of volatile substances into the gas phase with subsequent injection of gas samples into the chromatograph. Another possibility is to use the mode of multiple (up to 10 times) concentration of a gas sample with subsequent analysis. The use of an additional module for cryofocusing of gas samples in the capillary column of the chromatograph makes it possible to further reduce the limits of detection of analytes.

Static headspace models Agilent 7697A

7697A allows multiple (up to 100 times) extraction of volatile substances into the gas phase with subsequent insertion of gas samples into the chromatograph. Another possibility is to use the mode of multiple (up to 10 times) concentration of the gas sample with subsequent analysis. The use of an additional module for cryofocusing gas samples in the capillary column of the chromatograph makes it possible to further reduce the detection limits of the analyzed substances.